Adonia Verlag: Atomic clock comparisons with a 3e 10-16 uncertainty via geostationary satellite - Riedel, Franziska - Schünemann

Atomic clock comparisons with a 3e 10-16 uncertainty via geostationary satellite

PTB-Berichte. Optik (Opt) 90
Schünemann
ISBN 9783956065644
154 Seiten, Taschenbuch/Paperback
CHF 24.20
Wird für Sie besorgt
Optical clocks are superior to all other clocks, reaching 10-18 in their uncertainty.

This makes them not only attractive for the field of fundamental research, like testing

General Relativity or examining the variance of fundamental constants, but marks

them also as potential candidates for the new definition of the second. An essential step towards that direction is the possibility to carry out comparisons of optical

clocks at remote sites to have consistency checks of clocks constructed mostly independently by different groups.

Satellitebased techniques offer the possibility of simultaneous comparisons over a

large variety of baselines. Their instability, however, has been demonstrated to be

in the low 10-15 range at 1 d averaging time for most measurements. In case of

twoway satellite time and frequency transfer (TWSTFT), the instability is limited

by the modulation bandwidth of the signal. For this work, the full bandwidth of

20 Mchip/s of the commonly used TWSTFT equipment, a SATRE modem, is employed, providing a potential improvement of a factor of 20 with respect to the currently performed TWSTFT measurements for the time scale comparisons contributing to TAI.

This technique is used in this work to compare five optical clocks and six microwave

fountain clocks located at four different European metrology institutes simultaneously over a period of 26 d. In order to prepare this measurement, extensive studies

on the SATRE modem are carried out and presented, and other aspects that need

to be taken into account for TWSTFT measurements with low instabilities are discussed, such as atmospheric delays, geometric and relativistic effects and laboratory

and roof station setups.

The link instability of TWSTFT during the measurement campaign is presented, and

compared to the instability of GPS Precise Point Positioning, that is implemented as

an additional, independent comparisons technique for the campaign.

Relative frequency differences of the optical and the fountain clocks are calculated.

For that, a processing was introduced that combines phase and frequency data of

different noise types and gaps. A respective estimator for the statistical uncertainty,

based on the correlation on the data, is established. The results of both satellitebased techniques show good agreement with each other, and also clocks based on

the same frequency transition agree within a 1-s-uncertainty. The overall uncertainties obtained for TWSTFT are between 2.7 × 10-16 and 3.5 × 10-16 for the optical

clock comparisons. Limitations for the uncertainties of the measurements are discussed in detail, the available satellite-based techniques are evaluated with respect

to their advantages and drawbacks for similar measurements in the future.

Keywords: Frequency comparison, TWSTFT, Optical clock